An experimental investigation has been performed to study the effect of hole shape and position on the cooling performance of a gas turbine stator. Two rows of laid-back fan-shaped holes are placed on the pressure side of a scaled vane in a two-dimensional cascade and compared with two identical rows of standard cylindrical exit. Both hole shapes have the same base diameter and were investigated at three different blowing ratios (1, 1.35, and 1.7) with the same coolant flow rate used in each case. The experiments are conducted for the first row of holes only, then for the second row only, and finally for both two rows together at a 0.9 density ratio. The mainstream inlet Reynolds number based on the true chord is 1.4E5 and the exit Mach number is 0.23. The local distributions of the heat transfer coefficient and film cooling effectiveness are obtained using a transient TLC technique. The second row of holes, with by a higher local radius of curvature, shows a 40% decrease in the cooling effectiveness as well as a 10% increase in the heat transfer coefficient near downstream of the hole compared with that obtained by the first hole. The double injection provides a slight increase in the cooling effectiveness and a lower heat transfer coefficient due to the favorable interaction between both injections.
Skip Nav Destination
ASME 2012 International Mechanical Engineering Congress and Exposition
November 9–15, 2012
Houston, Texas, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4523-3
PROCEEDINGS PAPER
Experimental Investigation of Double Rows Film Cooling on Vane Pressure Side
T. Elnady,
T. Elnady
Concordia University, Montreal, QC, Canada
Search for other works by this author on:
I. Hassan,
I. Hassan
Concordia University, Montreal, QC, Canada
Search for other works by this author on:
L. Kadem,
L. Kadem
Concordia University, Montreal, QC, Canada
Search for other works by this author on:
T. Lucas
T. Lucas
Pratt and Whitney Canada, Longueuil, QC, Canada
Search for other works by this author on:
T. Elnady
Concordia University, Montreal, QC, Canada
I. Hassan
Concordia University, Montreal, QC, Canada
L. Kadem
Concordia University, Montreal, QC, Canada
T. Lucas
Pratt and Whitney Canada, Longueuil, QC, Canada
Paper No:
IMECE2012-85875, pp. 1917-1926; 10 pages
Published Online:
October 8, 2013
Citation
Elnady, T, Hassan, I, Kadem, L, & Lucas, T. "Experimental Investigation of Double Rows Film Cooling on Vane Pressure Side." Proceedings of the ASME 2012 International Mechanical Engineering Congress and Exposition. Volume 7: Fluids and Heat Transfer, Parts A, B, C, and D. Houston, Texas, USA. November 9–15, 2012. pp. 1917-1926. ASME. https://doi.org/10.1115/IMECE2012-85875
Download citation file:
25
Views
Related Proceedings Papers
Related Articles
Effect of Unsteady Wake on Detailed Heat Transfer Coefficient and Film Effectiveness Distributions for a Gas Turbine Blade
J. Turbomach (October,1998)
Investigation of Detailed Film Cooling Effectiveness and Heat Transfer Distributions on a Gas Turbine Airfoil
J. Turbomach (April,1999)
Aerothermal Performance of a Cooled Winglet at Engine Representative Mach and Reynolds Numbers
J. Turbomach (January,2013)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Studies Performed
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential