An optical MEMS sensor device was developed to measure the relative slip range during fretting fatigue in hydrogen. The relative slip range is an important parameter to understand the mechanism of fretting fatigue failure, but there are measurement difficulties in a hydrogen environment. The MEMS sensor we developed showed a good reproducibility, accuracy and stability in hydrogen. For further improvement of the measurement, a calibration of the elastic deformation was done by both experiments and calculations. By applying this MEMS sensor, it was found that the relative slip range in hydrogen was significantly lower than that in air. This result...